Firmware configuration Use the local RESTAPI to configure the Connect IT 4 device
Digi Connect IT® 4 User Guide
34
$ curl -k -u admin https://192.168.210.1/cgi-bin/config.cgi/value/service/ssh -X
GET
Enter host password for user 'admin':
{
ok": true,
"result": {
"type": "object",
"path": "service.ssh"
, "collapsed": {
"acl.zone.0": "internal"
,
"acl.zone.1": "edge"
,
"acl.zone.2": "ipsec"
,
"acl.zone.3": "setup"
,
"enable": "true"
,
"key": ""
,
"mdns.enable": "true"
,
"mdns.name": ""
,
"mdns.type": "_ssh._tcp."
,
"port": "22"
,
"protocol.0": "tcp"
}
}
}
$
You can also use the GET method to return the configuration parameters associated with an item:
curl -k -u admin https://192.168.210.1/cgi-bin/config.cgi/keys/service/ssh -X GET
Enter host password for user 'admin':
{ "ok": true, "result": [ "acl", "custom", "enable", "key", "mdns", "port",
"protocol" ] }
$
Use the POST method to modify device configuration parameters
and list arrays
Use the POST method to modify device configuration parameters
To modify configuration parameters, use the POST method with the path and value parameters.
$ curl -k -u admin "https://ip-address/cgi-
bin/config.cgi/value?path=path&value=new_value" -X POST
where: