Routing Virtual Router Redundancy Protocol (VRRP)
Digi Connect IT® 4 User Guide
293
(config network interface lan ipv4 surelink target 0)>
interface_timeout value
(config network interface lan ipv4 surelink target 0)>
where value is any number of weeks, days, hours, minutes, or seconds, and
takes the format number{w|d|h|m|s}.
For example, to set interface_timeout to ten minutes, enter either 10m or
600s:
(config network interface lan ipv4 surelink target 0)>
interface_timeout 600s
(config network interface lan ipv4 surelink target 0)>
The default is 60 seconds.
9. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
10. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Example: VRRP/VRRP+ configuration
This example configuration creates a VRRP pool containing two Connect IT 4 devices: