Serial port Configure UDP serial mode
Digi Connect IT® 4 User Guide
245
i. Add a destination:
(config)> add serial port1 upd destination end
(config serial port1 udp destination 0)>
ii. (Optional) Enter a description of the destination:
(config serial port1 udp destination 0)> description string
(config serial port1 udp destination 0)>
iii. Set the host name or IP address of the remote site to which data should be sent:
(config serial port1 udp destination 0)>hostname hostanme-or-IP-address
(config serial port1 udp destination 0)>
iv. Set the port number of the remote site to which data should be sent:
(config serial port1 udp destination 0)> port port
(config serial port1 udp destination 0)>
15. (Optional) Configure access control:
a. Return to the root configuration prompt by typing ...:
(config serial port1 udp destination 0)> ...
(config)>
b. Set the Access Control List:
n To limit access to specified IPv4 addresses and networks:
(config)> add serial port1 udp acl address end value
(config)>
Where value can be:
l A single IP address or host name.
l A network designation in CIDR notation, for example, 192.168.1.0/24.
l any: No limit to IPv4 addresses that can access the service-type.
Repeat this step to list additional IP addresses or networks.
n To limit access to specified IPv6 addresses and networks:
(config)> add serial port1 udp acl address6 end value
(config)>
Where value can be:
l A single IP address or host name.
l A network designation in CIDR notation, for example, 2001:db8::/48.
l any: No limit to IPv6 addresses that can access the service-type.
Repeat this step to list additional IP addresses or networks.
n To limit access to hosts connected through a specified interface on the Connect IT 4