Interfaces Wide Area Networks (WANs)
Digi Connect IT® 4 User Guide
74
(config network interface my_wan surelink actions 0)> max_
attempts int
(config network interface my_wan surelink actions 0)>
The default is 3.
l Set the time to wait before the next test is run. If set to the default value of 0s,
the test interval is used.
(config network interface my_wan surelink actions 0)> override_
interval int
(config network interface my_wan surelink actions 0)>
n reboot_device.
If reboot_device is selected, complete the following:
l Set the number of attempts for this recovery action to perform, before moving
to the next recovery action:
(config network interface my_wan surelink actions 0)> max_
attempts int
(config network interface my_wan surelink actions 0)>
The default is 3.
l Set the time to wait before the next test is run. If set to the default value of 0s,
the test interval is used.
(config network interface my_wan surelink actions 0)> override_
interval int
(config network interface my_wan surelink actions 0)>
n custom_action: Execute custom recovery commands.
If custom_action is selected, complete the following:
l Set the number of attempts for this recovery action to perform, before moving
to the next recovery action:
(config network interface my_wan surelink actions 0)> max_
attempts int
(config network interface my_wan surelink actions 0)>
The default is 3.
l Set the commands to run to attempt to recovery connectivity.
(config network interface my_wan surelink actions 0)> custom_
action_commands_modem "string"
(config network interface my_wan surelink actions 0)>
l Set the time to wait before the next test is run. If set to the default value of 0s,
the test interval is used.

Table of Contents