System administration Configure the system watchdog
Digi Connect IT® 4 User Guide
802
5. Set the number of test failures before the system reboots:
(config)> system watchdog num_failures int
(config)>
6. Configure the tests that the watchdog will perform:
a. The memory check is enabled by default. To disable:
(config)> system watchdog tests memory enable false
(config)>
b. Set the percentage of RAM usage that will trigger a warning:
(config)> system watchdog tests memory max_memory_warning int
(config)>
The minimum value is 60 percent, the maximum is 100 percent. The default is 90 percent.
c. Set the percentage of RAM usage that will trigger a reboot of the device:
(config)> system watchdog tests memory max_memory_critical int
(config)>
The minimum value is 60 percent, the maximum is 100 percent. The default is 95 percent.
d. To log memory usage with every watchdog memory usage test, enable log_memory:
(config)> system watchdog tests memory log_memory true
(config)>
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.