DMM-0200 Product User Guide
159 Swanson Road
Boxborough, MA 01719
Tel: 508-475-3400
Email: sales@dovermotion.com
Write: Set high speed setting for joystick control
Syntax:
Write: JOYHS [axis] = [value]
JOYHS [axis] = [variable]
Examples:
JOYHSX=10000 ;***High speed of X axis is set to 10,000 pps
JOYHSY=20000 ;***High speed of Y axis is set to 20,000 pps
JOYDEL[axis]
Description:
Write: Set maximum delta value of change in speed for joystick control
Syntax:
Write: JOYDEL[axis] = [value]
JOYDELaxis] = [variable]
Examples:
JOYDELX= 100 ;***Speed delta of X axis is set to 100 pps
JOYDELU=200 ;***Speed delta of Y axis is set to 200 pps
JOYNO[axis]
Description:
Write: Set negative outer limit for joystick control
Syntax:
Write: JOYNO[axis] = [value]
JOYNO[axis] = [variable]
Examples:
JOYNOX=-10000 ;*** negative outer limit of x-axis set to -10000
JOYNIX=-9000 ;*** negative inner limit of x-axis set to -9000
JOYPIX=9000 ;*** positive inner limit of x-axis set to 9000
JOYPOX=10000 ;*** positive outer limit of x-axis set to 10000
JOYNI[axis]
Description:
Write: Set negative inner limit for joystick control
Syntax:
Write: JOYNI[axis] = [value]
JOYNI[axis] = [variable]
Examples:
See JOYNO[axis]
JOYPI[axis]
Description:
Write: Set positive inner limit for joystick control
Syntax:
Write: JOYPI[axis] = [value]
JOYPI[axis] = [variable]
Examples:
See JOYNO[axis]