Commissioning Proline Prosonic Flow P 500 HART
100 Endress+Hauser
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry / User
interface
Factory setting
Measuring point configuration – Select configuration for the
measuring point.
• 1 measuring point
- signal path 1
• 1 measuring point
- signal path 2
*
• 1 measuring point
- 2 signal paths
*
Depending on the
sensor version
Medium – Select the medium. • Water
• Sea water
• Distilled water
• Ammonia NH3
• Benzene
• Ethanol
• Glycol
• Kerosene
• Milk
• Methanol
• User-specific liquid
• Air
*
• Liquid
hydrocarbons
*
Water
Medium temperature – Enter the medium temperature
for the installation.
–200 to 550 °C 20 °C
Sound velocity calculation mode The Liquid hydrocarbons
option is selected in Medium
parameter.
Select the process variable to
use to calculate the sound
velocity at installation.
• Fixed value
• API gravity
• Density
• Reference density
API gravity
Sound velocity The User-specific liquid
option is selected in Medium
parameter.
Enter the medium's sound
velocity for the installation.
200 to 3 000 m/s 1 482.4 m/s
API commodity group The Liquid hydrocarbons
option is selected in the
Medium parameter and the
API gravity option or Density
option or Reference density
option is selected in the Sound
velocity calculation mode
parameter.
Select the medium's API
commodity group.
• A - crude oil
• B - refined
products
• D - lubricating oils
A - crude oil
API gravity The Liquid hydrocarbons
option is selected in the
Medium parameter and the
API gravity option is selected
in the Sound velocity
calculation mode parameter.
Enter the medium's API gravity
for the installation.
0.0 to 100.0 °API 10.0 °API
Density The Liquid hydrocarbons
option is selected in the
Medium parameter and the
Density option is selected in
the Sound velocity calculation
mode parameter.
Enter the medium's density for
the installation.
Signed floating-point
number
1 000 kg/m³
Reference density The Liquid hydrocarbons
option is selected in the
Medium parameter and the
Reference density option is
selected in the Sound velocity
calculation mode parameter.
Enter the medium's reference
density for the installation.
Signed floating-point
number
1 000 kg/m³