Proline Prosonic Flow P 500 HART Technical data
Endress+Hauser 215
Data logging (line recorder):
Memory capacity for up to 1000 measured values is activated.
250 measured values can be output via each of the 4 memory channels. The recording
interval can be defined and configured by the user.
Measured value logs can be accessed via the local display or operating tool e.g. FieldCare,
DeviceCare or Web server.
For detailed information, see the Operating Instructions for the device.
Heartbeat Technology Order code for "Application package", option EB "Heartbeat Verification + Monitoring"
Heartbeat Verification
Meets the requirement for traceable verification to DIN ISO 9001:2008 Chapter 7.6 a)
"Control of monitoring and measuring equipment".
Functional testing in the installed state without interrupting the process.
Traceable verification results on request, including a report.
Simple testing process via local operation or other operating interfaces.
Clear measuring point assessment (pass/fail) with high total test coverage within the
framework of manufacturer specifications.
Extension of calibration intervals according to operator's risk evaluation.
Heartbeat Monitoring
Continuously supplies data, which are characteristic of the measuring principle, to an
external condition monitoring system for the purpose of preventive maintenance or
process analysis. These data enable the operator to:
Draw conclusions - using these data and other information - about the impact the
measuring application has on the measuring performance over time.
Schedule servicing in time.
Monitor the process or product quality, e.g. gas pockets.
For detailed information, see the Special Documentation for the device.
Petroleum Order code for "Application package", option EJ "Petroleum"
The most important parameters for the Oil & Gas Industry can be calculated and displayed
with this application package.
Corrected volume flow and calculated reference density in accordance with the "API
Manual of Petroleum Measurement Standards, Chapter 11.1"
A temperature measurement is required to calculate the corrected volume. The
measured values can be read in via the 4-20 mA input on the device, for example.
As a temperature measuring device, the resistance thermometer TST602 is
recommended. TMT82 is recommended for use in hazardous areas.
For detailed information, see the Special Documentation for the device. →  217.
Petroleum & Product
identification
Order code for "Application package", option EQ "Petroleum& Product identification"
The most important parameters for the Oil & Gas Industry can be calculated and displayed
with this application package. It is also possible to identify the product based on the sound
velocity or the reference density.
Corrected volume flow and calculated reference density in accordance with the "API
Manual of Petroleum Measurement Standards, Chapter 11.1"
A temperature measurement is required to calculate the corrected volume. The
measured values can be read in via the 4-20 mA input on the device, for example.
As a temperature measuring device, the resistance thermometer TST602 is
recommended. TMT82 is recommended for use in hazardous areas.
For detailed information, see the Special Documentation for the device. →  217.