4.6.5.45 <RSDUPLEX [F/H] Command
This command sets the operating mode of the RS-485 interface:
• F means FULLDUPLEX
• H means HALFDUPLEX
4.6.5.46 <EXTRATE [N]> Command
This command sets the transmission rate N for Nx64/RS-232/RS-485 interfaces.
For the Nx64 interface: N=1…128 (V.35/V.36/X.21) or N=1…7 (V.28), in this case the Nx64
data rate will be Nx64 kbps.
For the RS232 and RS485 interfaces: N is the baudrate (9600 for instance). N=1200…256000.
4.6.5.47 <AUTOLOOP OFF/ALL/DATA> Command
This command sets the autoloop mode.
• OFF means line 141 is ignored
• ALL means a local loop forced by line 141 is allowed. Data from line 103 is looped to line
104 and clock from line113 is looped to line 115 (use in TTC clocking mode)
• DATA means local loop forced by line 141 is allowed. Data from line 103 is looped to line
104.
4.6.5.48 <EXTCLOCK [SRC] [DIR]> Command
This command defines the Nx64 clocking modes.
SRC:
• NORMAL means clocked by DSL
• INT means clocked by internal oscillator
• TTC means clocked (Received Clock) by line 113 (Terminal Transmit Clock)
DIR:
• CO means Codirectional mode
• CONTRA means Contradirectional mode