User Manual LTU Orion 3
160
8.3 Environment
8.3.1 Climatic Conditions
Storage:
ETS 300 019-1-1 Class 1.2
(-25C … +55C)
Transportation:
ETS 300 019-1-2 Class 2.3
(-40C … +70C)
Operation:
ETS 300 019-1-3 Class 3.2
(-5C … +45C)
Higher Operation Temperature range available on request (-20°C … +80°C)
8.3.2 EMC and Safety Standards
EN 300386 V1.4.1:2008
EN 50121-4:2006
EN 60950-1:2006
EN 55022:2006, Class B
EN 55024/A2:2003
EN 61000-4-2/A2:2001
EN 61000-4-3:2006
EN 61000-4-4:2004
EN 61000-4-5:2006
EN 61000-4-6:2007
EN 61000-4-6/A1:2001
8.4 Physical Dimensions and Weight
Dimension PCB:
233(W)x220(D)x1.6(H) mm
Dimension Unit
262(W)x247(D)x30(H) mm
Weight
< 0.6kg for LTU
< 3.8kg in Minirack
< 3.3kg in UTT1