User Manual LTU Orion 3
101
After the reset unit will work with specified number of SHDSL channels.
4.6.5.40 <LICENSE> Command
This command shows the active licenses.
CP_01_CM>LICENSE
Current license status:
Extended PAM and baserates: Not activated
4.6.5.41 <LICENSE ADD> Command
This command activate a special functionality added by a license KEY, that you can get from the
manufacturer.
4.6.5.42 <RSIP> Command
This command configures the RS<->IP (Serial to Ethernet) function of the modem.
Syntax: RSIP [I/O] [addr] [IF]
RSIP [{mode}/ON/OFF] [IF]
RSIP SIGNALING {sign} [IF]
RSIP RTS [CTS/DCD] [IF]
RSIP BREAK [ON/OFF] [IF]
[I/O]: Defines which parameter to configure. Input (IN: local IP port that receive serial data
packets) or Output (OUT: remote IP address to forward serial data packets).
[addr]: IP port or IP address and port. For Input (IN) address [addr] is just a port number. For
Output (OUT) address [addr] is an IP address and port number, separated by a colon (:). For TCP
Server mode only an IP address should be specified. The port number should be in range from
1024 to 65535 inclusively. Port numbers below 1024 may be used as well as port numbers above
1024, but may conflict with another built-in services like SNMP or NTP. It's not recommended to
use ports below 1024.
{mode}: Selects the IP protocol and mode. Possible values are: UDP (use UDP protocol),
SERVER (work as TCP Server), CLIENT (work as TCP Client).
[ON/OFF]: Enables/Disables RS<->IP function
{sign}: Define the RTS/CTS signals operation mode and is only for RS-232 available. Possible
values are: OFF (CTS & RTS signals are not used), LOCAL (TCP: When UP local RTS is looped
to CTS), UDP (RTS is always looped to CTS), REMOTE (CTS input is transferred to the remote
RTS output and vice versa). If communication is not established RTS is low. This mode works
over both TCP and UDP protocols and should be enabled on both ends of connection
simultaneously.
[IF]: Selects corresponding serial RS interface. Possible values are RS1 (for first RS interface).
This parameter may be ommited when only one RS232/422/485 interface is available.
[RTS] Selects input/output pair for signalling. In normal conditions the RTS will trigger CTS and
DTR will trigger DCD. This parameter allows to change default operation the way whre RTS will
trigger DCD and DTR will trigger CTS.
NOTE: RSIP RTS [CTS/DCD] [IF] command available for 1xRS232 daughterboard only