User Manual LTU Orion 3
82
RR09 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR10 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR11 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR12 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR13 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
----------------------------------------------------------------------
CO_01_FMM>
Option C - Clears the status of the TLM table.
4.6.4.26 <TLM S [N:[Rnn-Rkk]] [ABC]> Command
This command sets some LTU reaction on external alarms of Regenerators.
N: Selected line
Rnn - Rkk: Regenerator or the range of regenerators to set reaction for.
Example: 'R1', 'R9', 'R04', 'R1-R4', 'R07-R09'.
ABC: List of reactions. Must be a string of three digits, each from 0 to 3. First digit
corresponds to the first alarm, second - to second, third - to third.
Possible Values:
0 - no reaction.
1 - LTU will show this alarm by 'TLM' command.
2 - LTU will indicate minor remote alarm and show this alarm by 'TLM' command.
3 - LTU will indicate major remote alarm and show this alarm by 'TLM' command.
CO_01_FMM>TLM S 1:R1 213
Reactions on external alarms
---------- Line 1 -------- Line 2 -------- Line 3 -------- Line 4 ----
| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3|
----------------------------------------------------------------------
RR01 | MIN RES MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR02 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR03 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR04 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR05 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR06 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR07 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR08 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR09 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR10 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR11 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR12 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR13 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
----------------------------------------------------------------------
CO_01_FMM>
4.6.4.27 <POWER DIAG> Command
This command shows the diagnostic information for the remote power. It shows each remote
power source configuration, voltage, whether it is turned ON in configuration or actually now. It
also shows detailed remote power alarms and leakage current. The alarms are:
CUR - remote power CURrrent limit is exceeded.
DCL - 'DC leakage' current value is beyond normal limits (300uA max).
ACL - 'AC leakage' current value is beyond normal limits (700uA rms max).
ACM - 'AC Mains'-leakage current with industrial frequency value (50Hz, 60Hz, 16.67Hz) is
present and is above 500uA rms.
Leakage currents are measured on a per-remote power supply basis, so for 2x120VDC mode it
may be required to unplug one DSL channel to find the channel with leakage current or source of
industrial noise.
The DC leakage alarm is the sign that somewhere the wire line insulation is broken and there is
conducting path between the wire and ground or any other potential. The AC leakage and