Maintenance and Specifications
Specifications 9
9-29
Loss/Length Specifications (cont.)
Specification
DTX-MFM
Multimode Modules
DTX-SFM
Singlemode Modules
Length measurement accuracy ± 1.5 m plus ± 2 % of length
Propagation time accuracy ± 15 ns plus ± 2 % of propagation time
Output power (nominal) -20 dBm - 7 dBm
Output power stability over 8-hour
period (after 5 minute warmup)
± 0.10 dB over 8 hours, 5 minute
warm-up time
± 0.25 dB over 8 hours, 5 minute
warm-up time
Detector type InGaAs
Calibrated wavelengths 850 nm, 1310 nm, 1550 nm
Power measurement range 850 nm: 0 dBm to -52 dBm
1300/1310 nm, 1550 nm: 0 dBm to -60 dBm
Display Resolution dB, dBm: 0.01
Linear (µW): >400, >40, >4, >0.4, 0.4: 1, 0.1, 0.01, 0.001, 0.0001