EasyManua.ls Logo

Fluke DTX Series - Page 224

Fluke DTX Series
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DTX Series CableAnalyzer
Technical Reference Handbook
9-30
Loss/Length Specifications (cont.)
Specification
DTX-MFM
Multimode Modules
DTX-SFM
Singlemode Modules
Power measurement uncertainty (accuracy) ± 0.25 dB
1
Measurement linearity
(18 °C to 28 °C constant temperature)
1300/1310 nm and 1550 nm: ±0.1 dB
2
850 nm: ±0.2 dB
3
Dynamic Range for main-remote communication
and nominal length measurement
12 dB 22 dB
Re-calibration period 1 year
Display update rate 1 reading per second
1. Under the following conditions:
Power level: -20 dBm, continuous wave
At 850 nm: 62.5/125 µm fiber with 0.275 NA
At 1310 nm and 1550 nm: 9 /125 µm
Ambient temperature: 23
o
C ±5
o
C
2. Linearity for 1310 nm and 1550 nm:
Between 0 dBm and -55 dBm: ± 0.1 dB
< -55 dBm: ± 0.2 dB
3. Linearity for 850 dBm:
Between 0 dBm and -45 dBm: ± 0.2 dB
< -45 dBm: ± 0.25 dB

Table of Contents