29
NOTE:
Make sure that the target setting in the instrument matches the type of target used.
If the objective lens is dirty, it will affect the accurate of measured results. Dust it off
with your special brush and wipe it with your special cloth (in your carrying case)
before putting away.
If an object with a high reflective factor (metal, white surface) exists between the
instrument and the target when measuring, the accuracy of the measured results will
be affected.
An angle is also able to be measured when distance measurement.
Measurement will automatically stop after a single measurement if the EDM mode is
single (Fine “S” / Rapid “S”).
If the distance measurement mode is average “Fine AVG”, the measured distances are
displayed as “-1”,”-2”,”-3”…”-9” in turn, and the average value will display behind
“-A” once the selected time’s measurement has been finished.