14.3.2 Checking the water level and topping up water
Check the water level in the sealer regu-
larly.
Make sure the sealer is always filled at least
to the “Min” mark to prevent the felts from
drying up. When felts with glue residues dry
up they harden to the point of becoming pre-
maturely useless.
Topping up water
Separate the sealer from the postage
meter: Slightly lift the postage meter on the
left side and pull the sealer away to the left.
Swing up the rocker with the moistening
felt.
The filler hole for topping up the sealer is now
accessible.
Top up sealer with tap water.
Check the water level.
The water level in the sealer should
roughly reach to the “Max” mark.
Swing down the rocker.
If necessary: dry the sealer outside.
Connect the sealer to the postage meter.
Francotyp-Postalia offers a special bottle
with filling hose as accessory. This bottle lets
you top up the sealer right at the installation
site.
Lateral water
level gauge
Rocker with
moistening felt
Filler hole