Tips for troubleshooting
157
with automatic feeding / sealing (PostBase Vision Feeder)
Envelopes are not sealed. Sealing is disabled.
Set the switch to the “seal” position (see chapter 6.3.3.2).
Sealant tank is empty.
Fill more SEALIT sealing liquid (see chapter 16.9.1).
Envelopes are not properly
sealed.
Stroke your hand firmly over the envelope’s / letter
stack’s flap area.
Moistening sponge and brush are dried because
the sealant tank was empty over a longer period of
time.
Remove basket with sponge and let sponge soak
up completely (see chapter 16.9.3).
Sponge is dirty or worn.
Clean or replace the sponge (see chapter 16.9.3).
Brush is dirty or worn.
Clean or replace the brush (see chapter 16.9.4).
You have used unsuited envelopes.
Only use envelopes that are suited for sealing by
machine. Observe specifications (see page 180).
Adjust the moistening level (see chapter 16.9.2)
Use SEALIT, the special sealing liquid available
from Francotyp-Postalia.
Jam. On how to clear a letter jam, please read chapter 17.3.
Letters are not
correctly fed.
When processing thick letters (> 0.24" / 6 mm), use
the “thick letters’ function (see chapter 6.3.3.3).
Use the pendulum to press down the letter stack
(see page 72).
Adjust the ramp inclination (see page 70).
Issue Possible cause and remedy