EasyManuals Logo

Fronius TPS 270i C User Manual

Fronius TPS 270i C
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
107
EN
Process parame-
ters for Process
Mix
The following process parameters for mixed processes can be set under "Process mix":
Mixed process between PMC and LSC welding process. A cold LSC process phase follows a hot PMC process
phase as part of a cycle.
Mixed process between PMC and wire movement reversal using a PushPull drive unit. A cold low power phase
with calibration movement follows a hot PMC process phase.
Mixed process between CMT and PMC welding process. Cold CMT process phases follow hot PMC process pha-
ses.
(1) Lpc - Lower power correction
(2) Lptc - Lower power time correction
(3) Hptc - Upper power time correction
(1)
(2) (3) t [ms]
I [A]
PMC mix
v
D
[m/min]
(1)
(2) (3)
I [A]
PMC mix drive
v
D
[m/min]
t [ms]
(1)
(2) (3)
t [ms]
I [A]
CMT mix
v
D
[m/min]