116
The following can now be set and carried out on the JobMaster welding torch:
- Mode
- SynchroPulse
- Gas test
Setting the mode
for spot welding
Select Setup menu / Settings / System / SPm
Press the adjusting dial
Turn the adjusting dial and select the desired mode for spot welding
2-step = spot welding in 2-step mode:
The spot welding process runs for as long as the torch trigger is kept pressed and ends
no later than at the expiry of the spot welding time.
Releasing the torch trigger stops the spot welding process before the spot welding
time expires
4-step = spot welding in 4-step mode:
The spot welding process starts once the torch trigger is pressed and ends no later
than at the expiry of the spot welding time.
Press the torch trigger again to stop the spot welding process before the spot welding
time expires.
Press the right adjusting dial
To exit the Setup menu, press the "Welding process" and "Mode" buttons at the same
time
More information on spot welding:
- Page 81 (spot welding in general)
- Page 100 (spot welding time)
1
2
3
4
5