Process parameters
Process parame-
ters for start of
welding/end of
welding
The following process parameters can be set and displayed for the start and end of weld-
ing:
I-S
Starting current
For setting the starting current for MIG/MAG welding (e.g. aluminium welding start-up)
Setting range: 0 - 200% (of welding current)
Factory setting: 135%
AlS
Start arc length correction
For correcting the arc length at the start of welding
Setting range: -10 - +10% (of welding voltage)
Factory setting: 0
- .... shorter arc length
0 ... neutral arc length
+ ... longer arc length
t-S
Starting current time
For setting the length of time the starting current is to be active
Setting range: off / 0.1 - 10.0 s
Factory setting: off
SL1
Slope 1
For setting the time during which the starting current is decreased or increased to the weld-
ing current
Setting range: 0 - 9.9 s
Factory setting: 1 s
SL2
Slope 2
For setting the time during which the welding current is decreased or increased to the final
current.
Setting range: 0 - 9.9 s
Factory setting: 1 s
I-E
Final current
For setting the final current so that
a) heat build-up towards the end of welding is prevented and
b) the end-crater can be filled when welding aluminium
Setting range: 0 - 200% (of welding current)
Factory setting: 50

Table of Contents

Other manuals for Fronius TPS 270i C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TPS 270i C and is the answer not in the manual?

Fronius TPS 270i C Specifications

General IconGeneral
BrandFronius
ModelTPS 270i C
CategoryWelding System
LanguageEnglish

Related product manuals