EasyManua.ls Logo

Fronius TPS 270i C - Process Parameter Configuration

Fronius TPS 270i C
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
93
EN
Process parameters
Process parame-
ters for start of
welding/end of
welding
The following process parameters can be set and displayed for the start and end of weld-
ing:
I-S
Starting current
For setting the starting current for MIG/MAG welding (e.g. aluminium welding start-up)
Setting range: 0 - 200% (of welding current)
Factory setting: 135%
AlS
Start arc length correction
For correcting the arc length at the start of welding
Setting range: -10 - +10% (of welding voltage)
Factory setting: 0
- .... shorter arc length
0 ... neutral arc length
+ ... longer arc length
t-S
Starting current time
For setting the length of time the starting current is to be active
Setting range: off / 0.1 - 10.0 s
Factory setting: off
SL1
Slope 1
For setting the time during which the starting current is decreased or increased to the weld-
ing current
Setting range: 0 - 9.9 s
Factory setting: 1 s
SL2
Slope 2
For setting the time during which the welding current is decreased or increased to the final
current.
Setting range: 0 - 9.9 s
Factory setting: 1 s
I-E
Final current
For setting the final current so that
a) heat build-up towards the end of welding is prevented and
b) the end-crater can be filled when welding aluminium
Setting range: 0 - 200% (of welding current)
Factory setting: 50