9. Power Control Setup
Perform power control settings as required.
Power control settings must be performed if the Auto Power function (AC automatic linkage mode) is enabled,
the Power Resume function (automatic power recovery mode) is enabled, the power synchronized unit is
connected, or the Wake On LAN function is used.
Setup of the Auto Power Function and/or the Power Resume
Function
To automatically turn on the ETERNUS DX when AC power is supplied or when power is restored after a power
failure, use ETERNUS Web GUI to enable the Auto Power function and/or the Power Resume function.
โข Auto Power function (AC automatic linkage mode)
When the Auto Power function is enabled, the ETERNUS DX is automatically turned on when AC power is
supplied.
The Auto Power function is disabled for the factory default setting.
โข Power Resume function (automatic power recovery mode)
When the Power Resume function is enabled, the ETERNUS DX is automatically turned on when the power
supply is restored after a power failure.
The Power Resume function is disabled for the factory default setting.
Table 9 shows how the ETERNUS DX operates when the Auto Power function and the Power Resume function are
enabled or disabled.
Table 9
ETERNUS DX Operation according to the Settings of the Auto Power Function and the Power Resume
Function
Settings for the power control functions How the ETERNUS DX operates
Auto Power function is disabled
Power Resume function is disabled
The ETERNUS DX is not automatically turned on even when AC power is supplied
or when power is restored after a power failure.
Auto Power function is enabled
Power Resume function is disabled
The ETERNUS DX is automatically turned on when AC power is supplied.
The ETERNUS DX is not turned on even when power is restored after a power
failure.
Auto Power function is disabled
Power Resume function is enabled
The ETERNUS DX is not turned on automatically even when AC power is supplied.
The ETERNUS DX is automatically turned on when power is restored after a power
failure.
Auto Power function is enabled
Power Resume function is enabled
The ETERNUS DX is automatically turned on when AC power is supplied and when
power is restored after a power failure.
The procedure to enable the Auto Power function and the Power Resume function is described below.
1 On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
2 Click [System Settings] in [Category].
The [System Settings] screen appears.
3 Click [Setup Power Management] in [Action].
The [Setup Power Management] screen appears.
179 Configuration Guide (Basic)