EasyManua.ls Logo

Fujitsu ETERNUS DX S5 Series - Various Notification Settings; SNMP Trap Setup

Fujitsu ETERNUS DX S5 Series
259 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Various Notification Settings
To monitor an ETERNUS DX, perform the required settings for device error notification.
SNMP Trap Setup
SNMP Trap can be sent to the SNMP Manager (monitoring server) when an event occurs in the ETERNUS DX.
The SNMP Trap setting is explained below.
IMPORTANT
Carefully read this manual and the manuals for the monitoring software (SNMP Manager) that is to be
used before monitoring the ETERNUS DX.
โ– 
ETERNUS DX Settings
The SNMP Trap test setting is explained below.
1 Set up the network environment for the ETERNUS DX.
When the ETERNUS DX and the monitoring server are in different subnet environments, set the Gateway
IP address and the Allowable IP address (IP address of the monitoring server or the network address to
which the monitoring server belongs) on the [Setup Network Environment] screen of ETERNUS Web GUI.
The following procedure shows an example when selecting the [IPv4 Settings] tab.
2 Set up the SNMP environment.
(1) On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
(2) Click [Network] in [Category].
The [Network] screen appears.
8. Monitoring Settings
Various Notification Settings
161 Configuration Guide (Basic)

Table of Contents

Other manuals for Fujitsu ETERNUS DX S5 Series

Related product manuals