โ Messages That Are Displayed While Running (or Operating)
The message format that is displayed on the LCD panel while running (or operating) is shown in Figure
29.
Figure 29 Message Format of the LCD Panel (While Running)
E r r o r -
X
X / Y Y
Y Y Y Y
Y
Y Y Y Y
Y Y Y Y Y Y Y
3
1 2
Top row
Bottom row
1
Overall state of the ETERNUS DX
2 Number of indicated alarms
3 System name of the ETERNUS DX or information of a component where an error has occurred
The meaning of the message in the top and bottom rows of the LCD panel is shown in Table 13.
Table 13
Meaning of the Message on the LCD Panel (While Running)
The displayed messages and their meaning
Top row Overall state of the ETERNUS
DX
Normal The ETERNUS DX is running normally.
Error A failed component exists in the ETERNUS DX.
Contact your maintenance engineer.
Warning A component requiring a preventive replacement exists
in the ETERNUS DX.
Contact your maintenance engineer.
WrtThrough The ETERNUS DX is in a Write Through state. Contact
your maintenance engineer.
If a failed component exists in the ETERNUS DX, the
Error or Warning display is given priority.
PinnedData Pinned data exists in the ETERNUS DX. Contact your
maintenance engineer.
If a failed component exists in the ETERNUS DX, the
Error or Warning display is given priority.
Number of indicated alarms The currently displayed alarm number and the total number of alarms are
displayed.
XX: Alarm number that is currently displayed
YY: Total number of alarms
Bottom
row
System name of the ETERNUS
DX or information of a
component where an error
has occurred
YYYYYYYYYYYYYYYY The system name of the ETERNUS DX is displayed when
running normally.
A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)
209 Configuration Guide (Basic)