Powering On
This section explains how to turn on the ETERNUS DX.
The following methods can be used to turn the power on:
• Via the power switch
Press the Power switch to turn on the ETERNUS DX.
The following methods can be used to turn the power on by linking with the server.
• Via the power synchronized unit
Use the power synchronized unit to turn on the ETERNUS DX.
• Via the Wake On LAN function
Use the Wake On LAN function to turn on the power.
Follow the procedure below to turn on the ETERNUS DX.
IMPORTANT
• After turning the power on, it takes approximately five minutes for the ETERNUS DX to reach the READY
state (READY LED [ ] turns on). This should be taken into consideration for scheduled operations.
Table 3
Time Required to Turn the Power On
Model
Deduplication/
Compression function
is disabled
Deduplication/
Compression function
is enabled
Unified configuration (*1)
VLAN/Bonding maximum
configuration
Normal Error Normal Error Normal Error Normal Error
DX60 S5 Approx. 5
minutes
Max. 18
minutes
— — — — — —
DX100 S5 Approx. 5
minutes
Max. 18
minutes
— — Approx. 10
minutes
Max. 40
minutes
Approx. 20
minutes
Max. 50
minutes
DX200 S5 Approx. 5
minutes
Max. 18
minutes
Approx. 9
minutes
Max. 22
minutes
Approx. 10
minutes
Max. 40
minutes
Approx. 20
minutes
Max. 50
minutes
DX500 S5 Approx. 5
minutes
Max. 18
minutes
Approx. 12
minutes
Max. 25
minutes
Approx. 10
minutes
Max. 42
minutes
Approx. 22
minutes
Max. 53
minutes
DX600 S5 Approx. 7
minutes
Max. 20
minutes
Approx. 15
minutes
Max. 28
minutes
Approx. 12
minutes
Max. 44
minutes
Approx. 24
minutes
Max. 55
minutes
DX900 S5
(*2)
Approx. 10
minutes
Max. 20
minutes
Approx. 14
minutes
Max. 24
minutes
— — — —
*1: The time required to turn the power on for the Unified configuration depends on the NAS configuration (or the number of
shared folders and the number of VLAN/Bonding configurations).
*2: The ETERNUS DX900 S5 supports the Compression function only.
• Before turning the server on, check that the ETERNUS DX and the network devices that connect the
ETERNUS DX and the server are all in READY status.
If the server is turned on while any of these devices are not in READY status, the server may not be able
to recognize the ETERNUS DX.
• To turn on the ETERNUS DX by linking with the server, the server must wait until the ETERNUS DX is in
the READY state.
• If the Auto Power function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is
automatically turned on when power is supplied to the ETERNUS DX.
• If the Power Resume function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is
automatically turned on after the power is restored.
5. General Settings
Powering On
70 Configuration Guide (Basic)