2 Check that the READY LED ( ) of the controller enclosure or the frontend enclosure is lit up.
ETERNUS DX60 S5/DX100 S5/DX200 S5 ETERNUS DX500 S5/DX600 S5
Controller enclosure
Drive enclosure
Frontend enclosure
ETERNUS DX900 S5
Controller enclosure
Drive enclosure
For details about the time required until the READY LED is turned on, refer to "Important" of
"Powering
On" (page 70).
When checking the connection between the administration terminal and the ETERNUS DX, execute the
"ping" command at the administration command prompt. An example of ping execution is shown below.
("192.168.1.1" is the default IP address for the ETERNUS DX)
ping 192.168.1.1
If the execution results in an error, check the network settings of the administration terminal.
IMPORTANT
When communication cannot be established even after the RMT port of Controller 0 (CM#0) is
connected to the LAN port of the PC terminal, make sure that the MASTER LED of Controller 0
(CM#0) is turned on. When two controllers are installed and the MASTER LED of Controller 1 (CM#1)
is turned on, use the RMT port of Controller 1 (CM#1).
5. General Settings
Powering On
72 Configuration Guide (Basic)