Commercial burglary alarm system unit (Grade B UL 1610)
Basic system using control panel 600-1040, SuperBus 2000 RF transceiver module (600-1025-01-95R), plus
the following:
• Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode door/window
sensor (60-499)
• SAW PIR sensor (60-639-95R), crystal PIR sensor (60-703-95R), or DS924i PIR sensor (60-511-01-
95)
• UL Grade A bell/housing, such as Ademco #AB12M or equivalent
• Immediate beeps set to on
• UL 98 options set to on
• Receiver failure set to on (if wireless devices are used)
• RF Tx timeout set to 4 hours
• 24-hour tamper set to on
• System tamper set to on
• Automatic phone test set to on
• Phone test frequency set to 1
• Next phone test set to 1
• Siren verify set to on
• AC failure set to on
• Exit delay set to 120 seconds or less
• Quick exit set to off
• Two-trip error set to off
• Alarm verify set to off
• Disable trouble beeps set to off
• Phone number must be programmed
• High level reports set to on
• Low level reports set to on
• Communication failure set to on
• Extended delay set to off
• Sleep time set to off
• Siren timeout set to 4 minutes or more
UL 1610 24-hour backup
Same as UL 1023 and 985.