Installation Manual
172
Table 31. Response characteristics
Response characteristics Description
Momentary trip time The point remains active for nn seconds (n is 1-12 seconds). The default is 4 seconds.
3 minute trip time The point remains active for three minutes.
Siren-time trip time The point remains active while the sirens are sounding.
Sustained trip time The point remains active for the duration of the event.
Siren pattern The point activates and deactivates according to the current alarm type:
Auxiliary: fast on/off/on
Police: constant on
Fire: repeating
Trip delay The point activates 30 seconds after the trigger event occurs.