EasyManuals Logo

GE Security Concord 4 Installation Manual

GE Security Concord 4
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
Concord 4
Installation Manual
54
High level reports (CS phone 1, 01001, CS phone 2, 01011, CS phone 3, 01021)
Default setting for 1 is On and Off for 2 and 3.
When this setting is on, the following conditions report to the central station:
Fire, police, auxiliary, and duress alarms
No activity
Receiver failure (or jam)
Tamper conditions, including zone tampers and system tamper (40 incorrect key presses or touchpad
supervisory)
Entering or exiting sensor test mode
Phone test
Note: For UL 1610 and 1635 installations, this feature must be set to on.
To turn high-level reports off or on, do the following:
1. With the display showing HIGH LEVEL RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Low level reports (01002, 01012, and 01022)
Default setting is On for 1 and Off for 2 and 3.
When this setting is on, the following nonalarm conditions report to the central station:
Force armed
Hardwired zone trouble (open or short)
Supervisory (wireless devices)
Low battery (wireless devices)
Phone test
Other nonalarm related conditions
Note: For UL 1610 & 1635 installations, this feature must be set to on.
To turn low-level reports off or on, do the following:
1.
With the display showing LOW LEVEL RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Exception reports (01003, 01013, and 01023)
Defaults setting is Off.
When this setting is on, the panel reports to the central station if the system is not armed or disarmed at the
specified schedule times.
To turn exception reports off or on, do the following
1. With the display showing EXCEPTION RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals