Page #98 background image
Concord 4
Installation Manual
88
Edit sensors (083)
Default setting is None.
This menu lets you view and, if desired, change the group and partition assignment for each learned zone or
sensor. For example, the display shows:
CODE 1> S01 P1 G13 NC HW BACK DOOR
.
Where S01 is the zone/sensor number, P1 is partition 1, G13 is sensor group 13, NC is normally closed, HW is
hardwired, and BACK DOOR is the programmed text name.
Other description codes include:
RF (wireless sensor)
TP (touchpad)
NO (normally open)
To edit sensors, do the following:
1. Press A or B until the display shows EDIT SENSORS.
2. Press # and the display shows the sensor or zone with the lowest number.
3. Press A or B to scroll through all learned zones and sensors.
4. When the desired zone or sensor is displayed, press #. The display shows SENSOR PTN n (current
partition assignment).
5. Enter the desired partition number, then press #. The display shows the new partition assignment.
6. Press A or B and the display shows SENSOR GROUP nn (current group assignment).
7. Enter the desired group number, then press #. The display shows the new group assignment.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals