Index
Z.4 EST3 Installation and Service Manual
remote power source • 3.44
transformer • 3.8
transformer source • 3.41
power wiring • 5.42
power-up procedure • 6.3
prealarm
setting • 1.27
preventive maintenance
schedule • 7.3
primary power supply • 8.7
priority
audio channel • 1.34
problem classification • 8.3
Proprietary using 3-MODCOM or FireWorks • C.7
Proprietarywith standard line security • C.7
proximity cards • 3.6
pseudo point descriptions • 8.24
R
rack mounting • 5.22
racks
equipment • 4.3
reader terminal dummy loads • 3.34
recommended spares list • 8.4
record of completion • 6.24
remote controls application • 3.45
remote power source application • 3.42
remote power supply wiring diagram • 3.44
request to exit buttons • 3.5, 3.18, 3.20
requirements for UL security applications • C.3
resetting the CRC • 3.18, 3.25
resistance of SAC bus • 3.3
resource allocation • 3.17
resource profiles • 3.7, 3.17
response lists • 8.56
RPM • 3.7, 3.17
S
SAC bus
3-SAC module • 3.3
description • 3.3
elevator control application wiring • 3.23
EOL resistor • 3.34
wiring • 3.3
SAC bus power calculations • B.21
SDU
configuring CRC • 3.8
CRCSND programming • 3.4
role in a security system • 3.8
second card reader • 3.26
security devices • 3.5
selecting a page destination • 1.35
selective page • 1.35
sensitivity fault • 8.63
sharing devices • 3.17
short fault • 8.64
SIGA-AAxx • 8.21
Signature
detector troubleshooting • 8.60
diagnostic tools • 8.51
module troubleshooting • 8.49, 8.61
real time status • 8.65
trouble tables • 8.62
Signature controller module • 3.46
Signature data circuit
basic troubleshooting • 8.37
branch length • B.5
determining total length • B.10
ground faults • 8.39
operation • 8.35
wire length • B.5
Signature relays
elevator control application • 3.21
remote controls application • 3.46
smart cards • 3.6
static-sensitive handling • 8.3
strict anti-passback • 3.11
strikes
description • 3.7
strobe
synchronization • 5.6
substituting hardware • 8.5
substituting known good Signature series devices •
8.41
synchronization of NACs • 5.6
system description • 1.2
T
testing
control and emergency communications • 6.7
initial and reacceptance • 6.6
initiating devices • 6.21
notification appliances • 6.23
timed anti-passback • 3.11
transformers
AC power source application • 3.39
circuit common • 3.8
CRCXF CRC Transformer • 3.5
elevator control application • 3.23
remote controls application • 3.46
wiring diagram • 3.41
trouble and maintenance log • 7.7
trouble registers • 8.59
trouble tables
Signature • 8.62
troubleshooting
wiring problems • 8.77
two-person rule
dual LED control • 3.6
two-person rule application • 3.47
U
UL and ULC requirements • C.10
UL security application requirements • C.3
unexpected fault • 8.63
uninterruptible power supply • 5.48
Universal Riser Supervisory Module • 4.10
unlock timer • 3.9
V
visitor access level • 3.31
visitor and escort
dual LED control • 3.6
multiple card readers application • 3.30
W
Wiegand pin cards • 3.6
wire length calculations
24 Vdc notification appliance circuits • B.11
25 or 70 Vrms notification appliance circuits • B.17