2018112-069 Rev. F eBike II, eBike II L, eBike II EL - 135 -
error Code BIts lre
Bit Error Reaction Display / Info Troubleshooting
0 To high rotation Warning none
- advise user to cycle less than 130 rpm
1 Load out of limit Warning - advise user to cycle between
30 and 130 rpm
- perform static calibration
2 DMS Offs. invalid Safety shut down - perform static calibration OFFSET
- if error persists:
replace strain gauge
3 DMS Gain invalid Safety shut down - perform static calibration GAIN
- if error persists:
replace strain gauge
4 +24V out of range Internal error - check power supply
- check connections:
power supply to LRE
cable ZME <-> LRE
(or ZME <-> BDE
BDE <-> LRE)
5 +5V out of range Safety shut down - restart eBike (OFF / ON)
- if error persists: replace LRE
6 Brake not released. Safety shut down - check connections:
LRE <-> brake
LRE <-> strain gauge
- perform static calibration
7 Safety state mode Safety shut down - restart eBike (OFF / ON)
- if error persists:
replace BDE
8 Setup not ready Internal error - restart eBike (OFF / ON)
- if error persists:
check cable ZME <-> LRE
or BDE <-> LRE
- replace LRE
9 CAN zykl. Timeout Safety shut down - restart eBike (OFF / ON)
- if error persists:
check cable ZME <-> LRE
or BDE <-> LRE
- replace LRE