- 46 - eBike II, eBike II L, eBike II EL 2018112-069 Rev. F
load unIt exCHange
Remove the ergometer housing (see detailed
description at the appropriate ergometer type)
Disconnect the patch cables and the power supply
cable from the LRE board
The load unit is xed with 6 Allen key screws at the
ergometer chassis.
Loose the screws with a ratchet - prevent the load
unit from falling down (weight approx.10 kg)