- 138 - eBike II, eBike II L, eBike II EL 2018112-069 Rev. F
error Code BIts CoM
Bit Error Reaction Display / Info Troubleshooting
0 not used
1 not used
2 not used
3 not used
4 +24V out of range Warning - check mounting of COM
(DSUB connector)
- check jumper on BKE
- check power supply
- check connections:
power supply to LRE
cable LRE <-> BKE
- replace COM
5 not used
6 not used
7 Safety state mode Module is switched off Internal error - restart eBike (OFF / ON)
- check mounting of COM
(DSUB connector)
- check jumper on BKE
- if error persists: replace COM
8 Setup not ready Module is switched off Internal error - check mounting of COM
(DSUB connector)
- check jumper on BKE
- restart eBike (OFF / ON)
- if error persists: replace COM
9 CAN zykl. Timeout Module is switched off Internal error - check mounting of COM
(DSUB connector)
- check jumper on BKE
- restart eBike (OFF / ON)
- if error persists: replace COM