- 70 - eBike II, eBike II L, eBike II EL 2018112-069 Rev. F
Set the calibrator unit to 110 rpm.
Wait approx. 20 seconds, until the load display is
stable
By using the arrow keys, input the actual value of the
calibrator (e.g. 55,0 Watt) at the ergometer.
Store the value with SET.
Set the ergometer to 400 Watt (via PC interface)
Wait approx. 20 seconds, until the load display is
stable
By using the arrow keys, input the actual value of the
calibrator (e.g. 412,5 Watt) at the ergometer.
Store the value with SET.
The successfull completion of the dynamic load calibration
is conrmed.
Stop the calibration unit.
dynaMic load calibration - 50 watt at 110 rpM
Dynamic Load Cal.
Set at 110 rpm / 50 Watt
Rotation: 50
DMS-Volt: 327 mV
LRE Load: 50 Watt
Dyn. Load 55,0 Watt
SET
dynaMic load calibration - 400 watt at 110 rpM
Dynamic Load Cal.
Set at 110 rpm / 400 Watt
Rotation: 50
DMS-Volt: 327 mV
LRE Load: 400 Watt
Dyn. Load 412,5 Watt
SET
dynaMic load calibration - finiShed
Dynamic Load Cal.
Rotation: 110
DMS-Volt: 1327 mV
LRE Load: 400 Watt
Calibration successfull