- 70 - eBike II, eBike II L, eBike II EL 2018112-069 Rev. F
• Set the calibrator unit to 110 rpm.
• Wait approx. 20 seconds, until the load display is
stable
• By using the arrow keys, input the actual value of the
calibrator (e.g. 55,0 Watt) at the ergometer.
• Store the value with SET.
• Set the ergometer to 400 Watt (via PC interface)
• Wait approx. 20 seconds, until the load display is
stable
• By using the arrow keys, input the actual value of the
calibrator (e.g. 412,5 Watt) at the ergometer.
• Store the value with SET.
The successfull completion of the dynamic load calibration
is conrmed.
• Stop the calibration unit.
dynaMic load calibration - 50 watt at 110 rpM
Dynamic Load Cal.
Set at 110 rpm / 50 Watt
Rotation: 50
DMS-Volt: 327 mV
LRE Load: 50 Watt
Dyn. Load 55,0 Watt
SET
dynaMic load calibration - 400 watt at 110 rpM
Dynamic Load Cal.
Set at 110 rpm / 400 Watt
Rotation: 50
DMS-Volt: 327 mV
LRE Load: 400 Watt
Dyn. Load 412,5 Watt
SET
dynaMic load calibration - finiShed
Dynamic Load Cal.
Rotation: 110
DMS-Volt: 1327 mV
LRE Load: 400 Watt
Calibration successfull