Simon Security System 3
The following table describes non-programmable (hard coded) system operation as 
required to meet ANSI-SIA CP-01 and is provided only for your reference.
Central Station Reporting
Note  
The communication path between the panel and the receivers listed below can be either 
DACT or internet. One is not a backup for the other.
The panel has been tested with the following central station receivers using SIA and 
Contact ID reporting formats:
Note  
Before beginning installa-
tion, installers must verify 
compatibility with the follow-
ing central station receivers.
• Radionics D6600 Central Station Receiver
• Sur-Gard Central Station Receiver with models SG-DRL2A and SG-CPM2
• CS5000 Digital Alarm Communicator Receiver
• Osborne-Hoffman (OH2000E) Network Receiver
UL Canada Listed Installations
This section describes the requirements for CUL (UL Canada) Listed installations.
Canadian Standards CSA Certified Accessories
Residential Burglary Alarm System Unit (ORD-C1023-1974)
Basic system as described for “UL 1023 Listed Installations” plus:
• Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/
Window Sensor (60-670)
• Option 39: Siren Timeout set to 5 minutes or more
Residential Fire Warning System Control Unit (ULC-S545-M89)
Basic system as described for “UL 985 Listed Installations” plus:
• Wireless Smoke Sensor 60-848-95 learned into sensor group 26
• Option 39: Siren Timeout set to 5 minutes or more
• For 24-hour backup, the total current draw for all connected devices is limited to 
33 mA (during normal standby conditions) using a 1.2 AH battery.
California State Fire Marshall Listed Installations
Applied for.
N/A Duress/Panic Code 57 58 Disabled Disabled
N/A Cross Zoning 71 58 Disabled Enabled for PIRs
Opt. 
#
Function Programming 
Page Reference
Testing Page 
Reference
Default 
Setting
Required Setting
Function Operation
Silent Exit All annunciators enabled
Remote Arming Exit Time & 
Progress Annunciation
All annunciators enabled
Abort Annunciation Enabled
Cancel Report Annunciation Enabled
Recent Closing Enabled (2 minute window)
Exit Error Enabled
Restoration of Power Panel resumes operation in same arming state 
and disregards alarm signals from sensors for the 
first 60 seconds after power restoration