EasyManua.ls Logo

GE Simon 60-875 - Option 86: Fire Alarm Verify; Option 87: 2-Way RF Touchpad Voice; Option 88: Custom Defaults; Option 89: Serial Port Protocol

GE Simon 60-875
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simon Security System
54
Option 86: Fire Alarm Verify
(Default = off)
Determines when a fire alarm is reported to the
central station.
If this option is on, a single smoke sensor must
stay in alarm for at least one minute before the
panel reports the alarm to the central station. If
a second (different) smoke sensor goes into
alarm before the Siren Timeout (Option 39)
expires, the panel immediately reports the
alarm to the central station.
If this option is off, the panel immediately
reports an alarm to the central station when a
smoke sensor goes into alarm.
¾
To turn on Fire Alarm Verify, press:
1. Add
2. Option #
3. 86
4. DONE
¾
To turn off Fire Alarm Verify (return to default), press:
1. Delete
2. Option #
3. 86
4. DONE
Option 87: 2-Way RF Touchpad Voice
(Default = off)
Determines the amount of broadcast speech that
is sent to 2-Way RF touchpads (Dialog QS1500
Touchtalk Interactive Keypad).
If this option is on, the panel will send broadcast
speech messages to the touchpads for arming,
disarming, alarm cancel and dialer abort events.
If this option is off, the panel only sends broad-
cast speech messages to the touchpads for voice
chime events.
See the Dialog QS1500 Touchtalk Interactive
Keypad Instructions (466-2105) for more infor-
mation on its use.
¾
To turn on 2-Way RF Touchpad Voice, press:
1. Add
2. Option #
3. 87
4. DONE
¾
To turn off 2-Way RF Touchpad Voice (return to default),
press:
1. Delete
2. Option #
3. 87
4. DONE
Option 88: Custom Defaults
Important !
DO NOT attempt to change or program this option without authorization from GE Security. Changing
this option could make your panel inoperable.
Option 89: Serial Port Protocol
(Default = off)
Determines if the Ethernet Interface module is
enabled.
If this option is on, the Ethernet Interface mod-
ule protocol on the serial port connector is
enabled.
If this option is off, the downloader protocol on
the serial port connector is disabled.
¾
To turn on Serial Port Protocol, press:
1. Add
2. Option #
3. 89
4. DONE
¾
To turn off Serial Port Protocol (return to default), press:
1. Delete
2. Option #
3. 89
4. DONE

Table of Contents

Other manuals for GE Simon 60-875

Related product manuals