EasyManua.ls Logo

GE Simon 60-875 - Option 38: Auto Arm; Option 39: Siren Timeout

GE Simon 60-875
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simon Security System 37
Option 38: Auto Arm
(Default = on)
Determines how long the system protests (announces open/failed sen-
sors) when attempting to arm with open/failed sensors, before bypassing
these sensors and automatically arming the rest of the system.
Note
The panel protests an arming attempt when it has not received a restore
(close) signal from sensors learned into restore-specific sensor groups. Sen-
sors learned into group 26 (Fire) cannot be bypassed. See “Sensor Group
Characteristics” in “Appendix B” to identify sensor groups with restore signal
requirements.
When this option is on, the panel announces all open/failed sensors
repeatedly for 4 minutes, then automatically bypasses the open sensors
and arms the rest of the system. If a sensor is opened during the exit
delay and then left open, the panel will go into alarm after the exit delay
has expired.
Note
This option must be on for Option 52 and 59: Unvacated Premises and Exit
Extension to work correctly.
If there are open sensors, pressing the ARM Doors & Windows button a
second time (before the 4-minute time expires) bypasses all open sen-
sors and arms the rest of the system. Pressing this button a third time
eliminates the entry delay.
If there are no open sensors, pressing the ARM Doors & Windows but-
ton a second time (before the exit delay expires) eliminates the entry
delay.
Note
For UL Listed systems, this option must be on.
When this option is off, the panel announces all open/failed sensors
once, then automatically bypasses the open sensors and arms the rest of
the system after the exit delay has expired. If other sensors are opened
during the exit delay, they will also be bypassed if left open.
Note
If a Group 13 (Instant Perimeter) sensor is opened during the exit delay, the
panel goes into immediate alarm.
¾To turn on Auto Arm, press:
1. Add
2. Option #
3. 38
4. DONE
¾
To turn off Auto Arm, press:
1. Delete
2. Option #
3. 38
4. DONE
Option 39: Siren Timeout
(Default = 004 minutes)
Determines how long sirens sound alarms if no one is
present to disarm the system.
The time can be set from 002 - 254 minutes. Entries
must be 3 digits. When this feature is turned off, sirens
sound alarms until the alarm is canceled (system is dis-
armed).
Note
For UL listed systems, Siren Timeout must be set to at least
4 minutes.
¾To set Siren Timeout, press:
1. Add
2. Option #
3. 39
4. Use the numbered keys to enter the time 002 - 254
minutes (all entries must be 3 digits).
5. DONE
¾
To turn off Siren Timeout, press:
1. Delete
2. Option #
3. 39
4. DONE

Table of Contents

Other manuals for GE Simon 60-875

Related product manuals