Simon Security System 7
Dealers - to simplify customer and account management.
First Responders - to identify where and how to respond.
Customers - to receive event notifications and to control their security system.
Dialog
Telephone Interface Module (DTIM) (60-879-95R)
Note
The DTIM doesn’t support
AVM, remote access or any
call back from the central
station. It is for reporting pur-
poses only.
The DTIM is a battery operated communication link between the security system con-
trol panel and the central monitoring station. The DTIM receives radio signals from
the panel, then uses the phone line to report security system events to the central sta-
tion.
* Not investigated for use by UL.
Planning
Sensor Types &
Locations
The first step to an easy and successful installation is to decide what areas or items to
protect, which lights or appliances to operate, and the best location for the panel,
touchpad, sensors, and sirens.
Metal objects, mirrors, and metallic wallpaper can block signals sent by the wireless
sensors. Make sure there are no metal objects in the way when installing the system.
Use the planning tables in “Appendix B” to determine the appropriate Sensor Type for
the sensors you will be adding. You’ll need to understand the application for each sen-
sor. For example, Keychain Touchpads are typically programmed as sensor group 01
(Portable panic), used to send an intrusion alarm to a central monitoring station. This
sensor type is instant intrusion, it does not require restoral or supervisory communica-
tion with the panel and it is active in 4 arming levels (disarm, arm doors & windows,
arm motion sensors, and arm doors/windows and motions sensors).
Device Locations
Control Panel
Locate the panel where alarm sounds can be heard and is easily accessible for opera-
tion.
Do not install the panel near a window or door where it can be reached easily by an
intruder.
Recommended Sensor Groups
Device Recommended Sensor Group
Keychain Touchpad 01, 03, 06, 07
ELM Keychain Touchpad 01, 03, 06, 07
Remote Handheld Touchpad 01, 03, 06, 07
QS1500 Keypad 01, 03, 06, 07
Indoor Motion Sensor 17 (intrusion), 25 (chime)
Outdoor Motion Sensor 25
Smoke Sensor 26
Exterior Door 10
Interior Door 14
Window Sensor 13
CO Alarm 34
Freeze Sensor 29
Water Sensor 38
RF Electronic Thermostat 36
Personal Help Button 01, 03
DTIM 08, 36