Simon Security System 41
Option 47: AVM Mode
(Default = off)
Determines whether the panel hangs up and waits for a 
callback from the central station operator before start-
ing an audio session (on), or stays on line with the cen-
tral station for an instant audio session (off).
Note  
Option 33: Audio Verification must be on for this feature to 
work.
¾To set AVM Mode to Callback, press:
1. Add
2. Option #
3. 47
4. DONE
¾
To set AVM Mode to Instant, press:
1. Delete
2. Option #
3. 47
4. DONE
Option 48: Panic Talk - AVM 
(Default = off)
Determines whether the central station operator can 
talk to the user during a silent alarm (off) or just listen 
in on the premises (on).
Silent alarms occur when sensors learned into groups 
02 or 03 are tripped, when the Panic Code is entered, 
or when the panel Police button is pressed and Option 
74: Silent Panel Police Panic is turned on.
Note  
Option 33: Audio Verification must be on for this feature to 
work.
¾To turn on Panic Talk - AVM, press:
1. Add
2. Option #
3. 48
4. DONE
¾
To turn off Panic Talk - AVM, press:
1. Delete
2. Option #
3. 48
4. DONE
Option 49: Arming LEDs Shutdown 
(Default = off)
Determines whether the panel LEDs (buttons) turn off 
30 seconds after the last button press (on), or remain 
on for the entire arming period (off).
¾
To turn on Arming LEDs Shutdown, press:
1. Add
2. Option #
3. 49
4. DONE
¾
To turn off Arming LEDs Shutdown, press:
1. Delete
2. Option #
3. 49
4. DONE