Simon Security System
16
Figure 12.Battery Connected in Compartment
Applying AC Power
Note
Make sure the outlet is not
controlled by a switch or that
it is not part of a ground fault
interrupt circuit (GFIC).
1. Remove the center screw from the outlet cover plate and hold the cover plate in
place.
2. Plug the transformer into the lower receptacle of the outlet so that the hole in the
transformer tab lines up with the outlet cover screw hole. The panel voice should
announce “Hello, system XX is OK”
3. Insert the cover plate screw through the transformer tab and the outlet cover plate.
Tighten the screw firmly.
Installing X10 Modules
Lamp and Appliance Modules
1. Set the unit code dial to a unit number different from all other X10 modules
(between 1 and 8).
2. Set the house code for the installation.
3. Plug the module into a wall outlet.
4. Plug the lamp/appliance into the module.
Universal Module
Note
See “Light and Appliance
Controls” to program a Key-
chain Touchpad to activate a
Universal Module controlled
device.
1. Set the unit code dial to a unit number different from all other X10 modules
(between 1 and 8).
2. Set the house code for the installation.
3. Set the module switches to momentary and relay only.
4. Connect the module terminals to the desired device terminals.
5. Plug the universal module into a wall outlet.
+
-
+
-
Black
Red
Use extreme caution when securing the transformer to a metal outlet cover.
You could receive a serious shock if a metal outlet cover drops down onto the
prongs of the plug while you are securing the transformer and outlet cover to
the outlet box.
Warning
!
Do not plug in appliances or lamps with 300-watt or larger bulbs into Lamp
Tighten the screws to the Battery Compartment securely. Failure to d
!