Simon Security System
30
Option 19: RF Timeout
(Default = 12 hours)
Determines the time period the panel must receive at least 
one supervisory signal from learned sensors before identify-
ing a sensor failure and sounding trouble beeps. Any sensor 
failure is reported immediately and again at the supervisory 
time (Option 72: Supervisory Time).
The timeout can be set from 02-36 hours. Entries must be 2 
digits.
Note  
Setting this feature to 2 hours (02) may cause false reports. For 
UL 1635 listed systems, RF Timeout must be set to less than 4 
(04) hours. For UL 1023 listed systems, RF Timeout must be set 
to less than 24 hours.
¾ To change RF Timeout, press:
1. Add
2. Option #
3. 19
4. Use the numbered keys to enter the time 02 - 36 
hours (all entries must be 2 digits).
5. DONE
¾
To reset RF Timeout (return to default), press:
1. Delete
2. Option #
3. 19
4. DONE
Option 20: Manual Phone Test
(Default = on)
Determines whether the user can perform a manual phone 
test to verify communication to a central station/pager (on), 
or not (off).
¾
To turn on Manual Phone Test, press:
1. Add
2. Option #
3. 20
4. DONE
¾
To turn off Manual Phone Test, press:
1. Delete
2. Option #
3. 20
4. DONE
Option 21: Opening Reports
(Default = off)
Determines whether the panel sends opening reports to a cen-
tral station or pager whenever the system is disarmed (on), or 
not (off).
¾
To turn on Opening Reports, press:
1. Add
2. Option #
3. 21
4. DONE
¾
To turn off Opening Reports, press:
1. Delete
2. Option #
3. 21
4. DONE