Simon Security System 63
4. When you finish testing the system, call the central station to verify that the 
alarms were received.
Dialog Telephone Interface Module (DTIM)
The following describes the basic steps for testing transmitting range from the DTIM 
to the panel. For complete testing instructions, see the DTIM installation instructions.
Note  
Be sure to attach the cover 
onto the DTIM before testing 
wireless communications.
1. Place the DTIM in the desired location, between 10 and 100 feet (3 and 30 
meters) from the panel.
2. Put the panel into sensor test mode (See “Sensor Testing). The panel should sound 
1 beep. This indicates good reception from the DTIM to the panel.
Note  
If you don’t hear a beep, test the DTIM in different locations. Mounting locations should be 
limited to areas where the panel responds with a beep. Also, you may not get any beeps if a 
neighboring Simon panel is in a downloading session with ToolBox
®
.
3. To retest transmitting range after relocating the DTIM (or after a neighboring sys-
tem is finished downloading), you must exit and re-enter sensor test mode.
4. Exit from test mode after determining acceptable locations.
Pager Communication
Use the following table to determine what the numeric message is reporting.
Sensor/User Reporting Codes
Arm or Disarm from: Reports as User:
Panel, Remote Handheld Touchpad or QS1500 Keypad 0
Keychain Touchpad 1-24 (sensor number)
Panel Aux Panic 25
Panel Tamper 26
Panel Police Panic 27
Panel Fire Panic 28
Utility Access Code 1 28
Utility Access Code 2 29
Master Code 30
Access Codes 1-5 31-35
Panic Code 36
Pager Reporting Message
Reports Numeric Message
Phone Test -101 -101
AC Power Restoral -102 -102
AC Power Failure -103 -103
Latchkey -104 -104
No Activity -105 -105
Panic Code -106 -106