Simon Security System 53
Option 82: Cooling Set Point
(Default = off)
If the room temperature rises above the Cool-
ing Set Point, the RF Electronic Thermostat 
will turn the air conditioner on until the room 
temperature returns to the Cooling Set Point.
The Cooling Set Point can be set between 51°F 
and 91°F
See the Dialog RF Electronic Thermostat 
Instructions (466-1931) for more information 
on its use.
¾
To adjust Cooling Set Point, press:
1. Add
2. Option #
3. 82
4. Use the numbered keys to enter 51 - 91.
5. DONE
¾
To turn off Cooling Set Point (return to default), press:
1. Delete
2. Option #
3. 82
4. DONE
Option 83: X10/RF Light Control
(Default = off)
Determines what type of light control will 
be used by the panel. 
If this option is on, the panel uses the GE 
RF light control modules to control lights.
If this option is off, the panel uses X10 
modules to control lights.
¾
To turn on X10/RF Light Control, press:
1. Add
2. Option #
3. 83
4. DONE
¾
To turn off X10/RF Light Control (return to default), press:
1. Delete
2. Option #
3. 83
4. DONE
Option 84: European Compliance
(Default = off)
For European installations.
Option 85: Smoke Supervision
(Default = off)
Determines how often the panel must receive 
supervisory signals from the smoke sensors.
If this option is on, the panel must receive at 
least one supervisory signal from smoke sen-
sors every four hours or it will identify a sensor 
failure and sound trouble beeps.
If this option is off, the time for receiving 
supervisory signals is determined by Option 
19: RF Timeout. 
Note  
For UL 985 listed systems, option 85 must be set 
to on.
¾To turn on Smoke Supervision, press:
1. Add
2. Option #
3. 85
4. DONE
¾
To turn off Smoke Supervision (return to default), press:
1. Delete
2. Option #
3. 85
4. DONE