Simon Security System
58
Access Codes (1 - 5)
The panel can have up to 5 secondary user access codes. These could be used by chil-
dren, a baby sitter, or a service person to disarm (or arm if Option 60 is on). These codes 
cannot be used for programming.
Panic Code
The Panic Code is able to arm, disarm, or subdisarm the panel and send a silent alarm to 
the Central Station. There will be no indication of an alarm at the panel.
Note  
Because different codes can be entered using the same button presses you have to use cau-
tion when programming the panic code. You need to ensure that the panic code does not use 
the same button presses as other access codes. For example if the master code is 1234, do 
not program the panic code to be 2244. The panel would interpret these codes to be the same 
code.
¾To add a code:
1. Press Add.
2. Press Access Code button. Continue pressing this button until you hear the access 
code to be changed.
3. Press DONE.
4. Enter the new access code by using the numbered keys. The panel announces the 
new code.
¾
To delete a code:
1. Press Delete.
2. Press Access Code. Continue pressing this button until you hear the access code to 
be deleted.
3. Press DONE. The panel announces the code is deleted.
Testing the 
System
This section describes how to perform the following test procedures:
• Control Panel
• Testing sensors
• Testing phone communication
• Testing central station communications
• Testing the X10 Lamp Modules
You should test the system after installing, after servicing, and after adding or removing 
devices from the system. 
Control Panel
Test the Control Panel by pressing the buttons as described below.
Note  
An access code is required 
when arming if Option 60: 
Secure Arming is on.
• ARM Doors & Windows-The panel arms Doors & Windows. Press twice to elimi-
nate the programmed entry delay. The button will blink when No Entry Delay is on.
• ARM Motion Sensors-The panel will arm Motion Sensors. Press twice to turn 
Latchkey on. The button blinks when Latchkey is on.
• DISARM -The panel will prompt you to enter an access code. Enter the appropriate 
code and the panel will disarm Doors, Windows, and Motion Sensors.
Important !  
40 keypresses for invalid 
codes (i.e. 10 invalid 4-digit 
codes) will cause a system 
access alarm. The alarm 
locks all touchpads, except 
keychains, for 90 seconds.
Arming Levels
Arming Level Description of Level
0 Sub-disarms (Master Access and Panic codes only), and 
bypasses 24 hour intrusion sensors (Master Access Code 
only). Fire sensors (group 26) cannot be sub-disarmed.