66
Keychain Touchpad: Press the LIGHT button repeatedly to turn all lights on and
off. The panel responds with Lights on/off.
Remote Handheld Touchpad/QS1500 Keypad: Press the Lights On button and
the unit # of the lamp module using the numeric buttons to test individual lamp
modules 1 - 8. The panel responds with Lights # on/off. Pressing the Lights On or
Off button twice, turns all the lights on or off.
X10 Siren and Lamp Module Functions
All sirens turn off when the system is disarmed or when the siren timeout expires. Siren
priority is as follows:
1. Fire (highest priority)
2. Intrusion
3. Emergency
Note
The X10 Siren must be set
to unit #9 to “hear” emer-
gency alarms and Status
Beeps. To “hear” emer-
gency alarms only, set to
unit #10.
If an alarm of greater priority occurs during an alarm of lower priority, the greater prior-
ity alarm sirens sound. Fire alarms sound a temporal 3 pattern (0.5 seconds on, 0.5 sec-
onds off for three beeps then 1.5 seconds off).
Emergency
Planning
Emergency Planning Floor Plan
Use these guidelines when drawing an emergency floor plan for the homeowner:
Show all building levels.
Show exits from each room (2 exits per room are recommended).
Show the locations of all security system components.
Show the locations of any fire extinguishers.
Alarm Siren and X10 Light Information
Fire Intrusion Emergency
X10 Lights Steady Flashing Steady
X10 Siren Steady Steady Alarm beeps
Interior & Panel Siren Temporal 3 Steady Fast on/off
Exterior Siren Temporal 3 Steady