Simon Security System
12
For circuit supervision, which allows the panel to detect if the siren wire is cut (open),
Option 53: Hardwire Siren Supervision must be turned on (see the “Programming” sec-
tion) and interior sirens must be wired with a resistor in the circuit.
LD105 Hardwire Interior Siren
Note
Do not install the resistor at
the panel terminals. This
does not provide supervision
of the wire.
Connect the LD105 Hardwire Interior Siren (13-374) to the panel using a 4.7k resistor
(included with siren) as shown in Figure 4. The resistor must be connected across the
siren wires as close to the siren as possible.
Note
If you are installing only an
interior siren and no exterior
siren and Option 53 is on,
you must connect a 4.7k
resistor between the HWIN2
and DCOUT terminals in
addition to the resistor
between HWIN1 and
DCOUT shown in Figure 4.
Figure 4. Hardwire Interior Siren with Supervision
Wiring Exterior Sirens
Panel terminal HWIN2 can be used for connecting exterior sirens and activates when
intrusion and fire alarms occur.
Exterior sirens can be wired with or without a resistor in the circuit for supervision. For
circuit supervision which allows the panel to detect if the siren wire is cut (open),
Option 53: Hardwire Siren Supervision must be turned on (see the “Programming” sec-
tion).
Hardwire Exterior Siren with Supervision
Note
Do not install the resistor at
the panel terminals. This
does not provide supervision
of the wire.
Connect the Hardwire Exterior Siren (13-046) to the panel using a 4.7k resistor
(included with siren) as shown in Figure 5. The resistor must be connected across the
siren wires as close to the siren as possible.
Note
If you are installing only an
exterior siren and no interior
siren and Option 53 is on,
you must connect a 4.7k
resistor between the HWIN1
and DCOUT terminals in
addition to the resistor
between HWIN2 and
DCOUT shown in Figure 5.
Figure 5. Hardwire Exterior Siren with Supervision
H W I N 2
H W I N 1D C O U T
A C A C
Red
Black
4.7k Resistor
(located at sire
n)
H W I N 2
H W I N 1D C O U T
A C A C
4.7k Resistor
(located at siren
)
Black
Red