Simon Security System 65
Voice Event Notification
Testing this feature requires two people; one at the alarm site and the other at the loca-
tion the panel is programmed to call (Options 5 and/or 43). The panel only reports
alarms and Latchkey when this feature is set up.
1. Contact the central monitoring station (if system is monitored) to inform them you
are testing the system and not to dispatch authorities.
2. At the system site, put the system into an alarm condition.
3. At the calling location, pick up the phone after it starts ringing. You should hear
the panel voice announce “Press star for alarm.”
4. Press
and the panel voice identifies the alarm. If there is more than one alarm
in progress, the user must press
for the panel voice to identify them.
Important !
You must terminate the call
by pressing
ƒ. Otherwise,
the panel may not discon-
nect from the phone line for
up to 2 minutes.
5. After all alarms have been identified, the panel announces “Press ƒ to exit.”
6. Press
ƒ to terminate the call.
RF Thermostat Operation
The following information is important for the RF Thermostat to function through
your control panel:
The panel needs to be armed to Level 4 (Doors & Windows and Motion Sensors)
for Energy Saving Mode to work.
If there are no Motion Sensors in the system, the Motion Sensors button must still
be pressed (armed to level 4).
Both options can be turned on at the same time.
Thermostat has to be in Auto Mode for Options 81 and 82 to work correctly.
If Options 81 and 82 are programmed, the RF Thermostat will go from Energy
Saving Mode to normal operating mode when the panel is armed to level 2.
Personal Help Button
The following information is important for the Personal Help Button to function
through your control panel:
Test the help button from several locations within the premises to check for a con-
sistent response.
Instruct the user to test the help button weekly
Decide how the user wants to access the help button (wall mount, belt clip, wrist
band or necklace)
For more information on the Personal Help Button refer to the Water Resistant Per-
sonal Help Button Installation Instructions (466-1815).
X10 Operation
The following sections describe how to test X10 Lamp, Siren, Appliance, and Univer-
sal Module operation.
Manual Lamp Module Control
Control Panel: Press the Lights On button and the unit # of the lamp module
using the numeric buttons to test individual lamp modules 2, 4, 6, and 8. The
panel responds with Lights # on/off. Press the Lights On button twice to turn on all
lamp modules. Press the Lights Off button twice to turn off all lamp modules.
If the system is monitored by a central station, contact them first before set-
Tighten the screws to the Battery Compartment securely. Failure t
!
ting off any alarms to avoid a false dispatch.