Simon Security System 49
Option 11: Exit Delay 045-254 seconds 005-254 seconds
Option 17: Dialer Delay 015-045 seconds 005-254 seconds
SIA Limits
Affected Option
SIA Limits
(Option 69 on)
Factory Ranges
(Option 69 off)
Option 70: Not Available
Option 71: Programming Report
(Default = off)
Determines whether the panel sends a report to the cen-
tral station anytime the programming mode is entered/
exited (on) or not at all (off).
The panel sends a report whenever the dealer (Utility
1) or installer (Utility 2) code is used to enter program-
ming mode and another report is sent when the pro-
gramming session ends (when the cover is closed).
¾
To turn on Programming Report, press:
1. Add
2. Option #
3. 71
4. DONE
¾
To turn off Programming Report, press:
1. Delete
2. Option #
3. 71
4. DONE
Option 72: Supervisory Time
(Default = 12:00am)
Determines when the panel reports supervisory
conditions (sensor failures) and automatic phone
tests to the central station.
Note
The panel clock must be set to the correct time for
this option and Option 16: Auto Phone Test to work
correctly.
¾To set Supervisory Time, press:
1. Add
2. Option #
3. 72
4. Press the Hours +/- buttons to select the correct hour.
5. Press the Minutes +/- buttons to select the correct minute.
6. DONE
¾
To turn off (disable) Supervisory Time, press:
1. Delete
2. Option #
3. 72
4. DONE