Simon Security System 21
5. Press DONE. The panel confirms your programming.
¾
To add a time-activated module:
1. Press Add.
2. Press Light Control.
3. Press Unit # until you hear the unit number that matches the one you chose on the 
module.
4. Press Time.
5. Press Hours and Minutes to set the beginning of the schedule.
6. Press DONE.
7. Press Hours and Minutes to set the end of the schedule.
8. Press DONE. The panel confirms your programming.
¾
To delete an Entry/Exit-activated module:
1. Press Delete.
2. Press Light Control.
3. Press Unit # repeatedly until you hear the unit number you want deleted.
4. Press Entry/Exit Delay, then press DONE. The panel confirms your program-
ming.
¾
To delete a sensor-activated module:
1. Press Delete.
2. Press Light Control.
3. Press Unit # repeatedly until you hear the unit number you want deleted.
4. Press Sensors until you hear the one you want deleted.
5. Press DONE. The panel confirms your programming.
¾
To delete a time-activated module:
1. Press Delete.
2. Press Light Control.
3. Press Unit # repeatedly until you hear the unit number you want deleted.
4. Press Time.
5. Press DONE. The panel confirms your programming
Ethernet Interface Module
Requirements
Note  
Devices between the Ether-
net Interface module and the 
transmission line (hub, 
router, cable modem, etc. 
must be UL listed and must 
not receive power from a 
switched outlet.
• Broadband Internet connection (DSL or cable modem)
• An available 10-Base-T or 10/100-Base-T Ethernet Port
Activate the Ethernet Interface Module
In order to program the module through the Simon panel you must activate the con-
nection between the panel and module. Activating the communication channel and 
gaining access to the module’s Remote Options is accomplished by turning Option 89 
On. Follow the instructions below to activate the module.
¾
To activate the Ethernet Interface module:
1. Enter Utility Access Code 1 (Dealer Code) if you are not already in program 
mode.
2. Press Add.
If connecting devices (“hub”, router, cable modem) do not have battery backu
the system will lose communication with the reporting station if AC power is lo
Caution
!