Simon Security System
22
3. Press Option #.
4. Press 8, then 9.
5. Press Done. The panel announces “Option 89 is on.”
6. Verify both the red and green LEDs on the module and ethernet connector are
blinking.
See Options 89-92 in this manual for custom programming options. See the Ethernet
Interface Installation Instructions (466-2161) for more information on this module.
Numbered Options
Numbered options let you customize system operation according to dealer and user
needs.
The “Option Settings” table in Appendix B lists all system options and their characteris-
tics. Fill in the last column of the table before programming to help speed up the pro-
gramming process.
Note
Although the panel voice
prompts you through pro-
gramming, it is not neces-
sary to wait for the complete
message before pressing
the next button in the pro-
gramming sequence.
There are two ways to reach the desired option setting.
•Press Add or Delete, then press Option # repeatedly until you hear the option you
want changed.
Or—
•Press Add or Delete, Option #, then enter the option number using the numbered
keys.
The following instructions use the last method.
Option 01: Panel Piezo Beeps
(Default = on)
Determines whether the panel piezo produces beeps based on sys-
tem activity (on) or is silent (off). The following table describes all
possible beeps.
Note
For all UL listed systems, Option 1 must be on (added).
¾ To turn on Panel Piezo Beeps, press:
1. Add
2. Option #
3. 01
4. DONE
¾
To turn off Panel Piezo Beeps, press:
1. Delete
2. Option #
3. 01
4. DONE
Panel Piezo Beeps
Activity Piezo Beep Response
ARM Doors & Windows Exit Delay—2 beeps sound every 5 seconds and 2
times per second during the last 10 seconds.
Silent Exit—2 beeps sound at the beginning of the
exit delay and 2 more sound just before the exit
delay expires.
Entry Delay—2 beeps sound every 5 seconds and 2
times per second during the last 10 seconds.